[{"data":1,"prerenderedAt":278},["ShallowReactive",2],{"blog-en-\u002Fen\u002Fblog\u002Famazeng-tmc-aba-ring-and-ball-blaine-apparatus":3},{"id":4,"title":5,"body":6,"description":256,"extension":257,"meta":258,"navigation":272,"path":273,"readingTime":274,"seo":275,"stem":276,"__hash__":277},"en_blog\u002Fen\u002Fblog\u002Famazeng-tmc-aba-ring-and-ball-blaine-apparatus.md","New in Amazeng TMC: ABA, Ring and Ball and Blaine",{"type":7,"value":8,"toc":246},"minimark",[9,14,34,57,60,64,71,78,110,114,120,127,158,162,168,175,206,210,230,234],[10,11,13],"h2",{"id":12},"the-tmc-family-grows","The TMC Family Grows",[15,16,17,18,23,24,28,29,33],"p",{},"Until now, ",[19,20,22],"a",{"href":21},"\u002Fen\u002Fproducts\u002Ftmc-test-machine-controller","Amazeng Test Systems (TMC)"," ran on press, tensile, ",[19,25,27],{"href":26},"\u002Fen\u002Fblog\u002Fcbr-test-zma","CBR"," and ",[19,30,32],{"href":31},"\u002Fen\u002Fblog\u002Fmarshall-stability-test-zma","Marshall"," test machines. Today we are adding three more instruments:",[35,36,37,45,51],"ul",{},[38,39,40,44],"li",{},[41,42,43],"strong",{},"ABA Asphalt Binder Analyzer:"," binder content of asphalt mixtures",[38,46,47,50],{},[41,48,49],{},"Ring and Ball:"," softening point of bitumen",[38,52,53,56],{},[41,54,55],{},"Blaine:"," fineness (specific surface) of cement",[15,58,59],{},"All three follow the same TMC approach: step-by-step guidance on a touchscreen, live charts, automatic calculation and an archive record for every test.",[10,61,63],{"id":62},"aba-asphalt-binder-analyzer","ABA Asphalt Binder Analyzer",[15,65,66],{},[67,68],"img",{"alt":69,"src":70},"ABA asphalt binder analyzer test screen","\u002Fproducts\u002Ftmc\u002Ftmc-aba-test.webp",[15,72,73,74,77],{},"ABA is built for ovens that determine the binder content of asphalt mixtures by the ",[41,75,76],{},"ignition method",". The sample burns on a scale inside the oven and the mass loss is tracked minute by minute. When the sample reaches constant mass, the test ends automatically and the binder content is calculated.",[35,79,80,86,92,98,104],{},[38,81,82,85],{},[41,83,84],{},"Standards:"," EN 12697-39, ASTM D6307 and AASHTO T308",[38,87,88,91],{},[41,89,90],{},"Oven settings:"," oven and afterburner set points, tare delay, ignition wait time, maximum test time",[38,93,94,97],{},[41,95,96],{},"Lift test:"," with the exhaust on, the scale is read for 20 seconds; the test passes if the reading is between -10 g and -3.2 g",[38,99,100,103],{},[41,101,102],{},"Correction factor:"," two samples with known binder content are burned and the factor is applied to the test parameters with a single tap",[38,105,106,109],{},[41,107,108],{},"Live monitoring:"," oven, afterburner, door lock and scale values with a mass loss (%) chart",[10,111,113],{"id":112},"ring-and-ball-softening-point-apparatus","Ring and Ball Softening Point Apparatus",[15,115,116],{},[67,117],{"alt":118,"src":119},"Ring and Ball softening point test screen","\u002Fproducts\u002Ftmc\u002Ftmc-ring-and-ball-test.webp",[15,121,122,123,126],{},"Ring and Ball automatically determines the softening point of bitumen by the ",[41,124,125],{},"ring and ball method",". Everything from bath conditioning to heating and archiving the result runs from a single screen.",[35,128,129,134,140,146,152],{},[38,130,131,133],{},[41,132,84],{}," EN 1427 and ASTM D36",[38,135,136,139],{},[41,137,138],{},"Bath:"," water or glycerin; the start temperature is selected automatically, with separate PID settings for each",[38,141,142,145],{},[41,143,144],{},"Step-by-step test:"," bath at 5 °C, rings in the bath for 15 minutes, balls on the rings, then heating",[38,147,148,151],{},[41,149,150],{},"Heating control:"," 5 °C\u002Fmin heating ramp with a live chart and a ±0.5 °C\u002Fmin tolerance cone",[38,153,154,157],{},[41,155,156],{},"Optical detection:"," left and right ball drops are detected separately by light barriers; the softening point, the difference between the two rings and the heating rate check are calculated automatically",[10,159,161],{"id":160},"automatic-blaine-apparatus","Automatic Blaine Apparatus",[15,163,164],{},[67,165],{"alt":166,"src":167},"Blaine cement fineness test screen","\u002Fproducts\u002Ftmc\u002Ftmc-blaine-test.webp",[15,169,170,171,174],{},"The Blaine apparatus measures cement fineness as specific surface (cm²\u002Fg) by the ",[41,172,173],{},"air permeability method",". Vacuum, timing, temperature tracking and calculation are fully automatic.",[35,176,177,182,188,194,200],{},[38,178,179,181],{},[41,180,84],{}," EN 196-6 (2 beds × 2 measurements) and ASTM C204",[38,183,184,187],{},[41,185,186],{},"Apparatus constant (K) calibration:"," 3 beds × 3 measurements with reference cement; the average K is applied with one tap and stored on the device",[38,189,190,193],{},[41,191,192],{},"Bed volume and temperature:"," bed volume by mercury displacement and a temperature offset against a reference thermometer; viscosity is taken into account at the measured temperature",[38,195,196,199],{},[41,197,198],{},"Automatic measurement:"," the pump draws the liquid to the top line and the time between the start and stop lines is measured automatically",[38,201,202,205],{},[41,203,204],{},"Result:"," specific surface rounded to 10 cm²\u002Fg with a bed-to-bed difference check",[10,207,209],{"id":208},"shared-features","Shared Features",[35,211,212,218,224],{},[38,213,214,217],{},[41,215,216],{},"Touchscreen:"," the operator is guided at every step, reducing errors",[38,219,220,223],{},[41,221,222],{},"Calibration screens:"," each instrument has its own calibration flow built into the software",[38,225,226,229],{},[41,227,228],{},"Archive:"," every test is saved automatically with its results",[10,231,233],{"id":232},"quotes-and-information","Quotes and Information",[15,235,236,237,240,241,245],{},"To modernize your existing equipment with TMC or set up a new test system, see the ",[19,238,239],{"href":21},"Amazeng Test Systems"," page or ",[19,242,244],{"href":243},"\u002Fen\u002Fcontact","contact us",".",{"title":247,"searchDepth":248,"depth":248,"links":249},"",2,[250,251,252,253,254,255],{"id":12,"depth":248,"text":13},{"id":62,"depth":248,"text":63},{"id":112,"depth":248,"text":113},{"id":160,"depth":248,"text":161},{"id":208,"depth":248,"text":209},{"id":232,"depth":248,"text":233},"Amazeng TMC now covers asphalt, bitumen and cement laboratories: touchscreen software for the ABA asphalt binder analyzer, the Ring and Ball softening point apparatus and the automatic Blaine apparatus.","md",{"date":259,"author":260,"readTime":261,"tags":262,"image":70,"translation":271},"2026-11-11","Amazeng Technical Team",5,[263,264,265,266,267,268,269,270],"Amazeng TMC","ABA","Ring and Ball","Blaine","Asphalt","Bitumen","Cement","Laboratory Equipment","amazeng-tmc-aba-ring-and-ball-blaine",true,"\u002Fen\u002Fblog\u002Famazeng-tmc-aba-ring-and-ball-blaine-apparatus",3,{"title":5,"description":256},"en\u002Fblog\u002Famazeng-tmc-aba-ring-and-ball-blaine-apparatus","2LfQ0T4gWL9mF1w6IJhX2zXzE-_-lPK9PbQeFMn3os8",1795417505889]