[{"data":1,"prerenderedAt":249},["ShallowReactive",2],{"blog-en-\u002Fen\u002Fblog\u002Fintroducing-conio-modbus-digital-io-module":3},{"id":4,"title":5,"body":6,"description":231,"extension":232,"meta":233,"navigation":244,"path":245,"readingTime":222,"seo":246,"stem":247,"__hash__":248},"en_blog\u002Fen\u002Fblog\u002Fintroducing-conio-modbus-digital-io-module.md","New Product: Conio Modbus Digital I\u002FO Module",{"type":7,"value":8,"toc":220},"minimark",[9,17,22,34,48,52,55,119,122,126,133,137,144,148,156,163,167,200,203,207],[10,11,12],"p",{},[13,14],"img",{"alt":15,"src":16},"Conio Modbus digital I\u002FO module","\u002Fproducts\u002Fconio\u002Fconio-front.webp",[18,19,21],"h2",{"id":20},"meet-conio","Meet Conio",[10,23,24,25,29,30,33],{},"There is a new member in the Amazeng product family: the ",[26,27,28],"strong",{},"Conio Modbus Digital I\u002FO Module",". Conio is a remote I\u002FO module that extends the digital inputs and outputs of your PLC, HMI or PC to the field over ",[26,31,32],{},"Modbus RTU on RS485",".",[10,35,36,37,42,43,47],{},"On the measurement side, ",[38,39,41],"a",{"href":40},"\u002Fen\u002Fproducts\u002Fzma-data-acquisition","ZMA"," and ",[38,44,46],{"href":45},"\u002Fen\u002Fproducts\u002Fgdt-digital-transmitter","GDT"," bring analog field signals into the digital world. Conio takes care of the other half: it reads buttons, sensors and limit switches, and drives valves, contactors and alarms.",[18,49,51],{"id":50},"two-channel-options","Two Channel Options",[10,53,54],{},"Conio comes in two versions:",[56,57,58,73],"table",{},[59,60,61],"thead",{},[62,63,64,67,70],"tr",{},[65,66],"th",{},[65,68,69],{},"Standard",[65,71,72],{},"Optional",[74,75,76,88,99,109],"tbody",{},[62,77,78,82,85],{},[79,80,81],"td",{},"Digital inputs",[79,83,84],{},"8, opto-isolated",[79,86,87],{},"16, opto-isolated",[62,89,90,93,96],{},[79,91,92],{},"Digital outputs",[79,94,95],{},"8",[79,97,98],{},"16",[62,100,101,104,107],{},[79,102,103],{},"Output type",[79,105,106],{},"Relay (2 A)",[79,108,106],{},[62,110,111,114,117],{},[79,112,113],{},"Communication",[79,115,116],{},"Modbus RTU (RS485)",[79,118,116],{},[10,120,121],{},"For most machine and cabinet applications 8 inputs \u002F 8 outputs are enough. When you need more points, the same module is available as a 16 \u002F 16 version.",[18,123,125],{"id":124},"opto-isolated-inputs","Opto-Isolated Inputs",[10,127,128,129,132],{},"Digital field signals often travel on long cables next to motors and drives. All of Conio's inputs are ",[26,130,131],{},"electrically separated by optocouplers",", so field-side noise and voltage spikes never reach the module's circuitry.",[18,134,136],{"id":135},"_2-a-relay-outputs","2 A Relay Outputs",[10,138,139,140,143],{},"All of Conio's outputs are ",[26,141,142],{},"2 A relays",". Because relays provide potential-free contacts, you can switch DC and AC loads at different voltage levels (valves, contactor coils, lamps, alarms) directly.",[18,145,147],{"id":146},"easy-integration-with-modbus-rtu","Easy Integration with Modbus RTU",[10,149,150,151,155],{},"Conio speaks ",[38,152,154],{"href":153},"\u002Fen\u002Fglossary\u002Fmodbus-rtu-tcp","Modbus RTU",", one of the most widely used protocols in industry. Your PLC, HMI panel, SCADA software or a PC can read Conio's inputs and write its outputs. Thanks to the multi-drop nature of RS485, several Conio modules can share the same line with GDT transmitters.",[10,157,158,159,33],{},"To learn more about Modbus integration, see our post on ",[38,160,162],{"href":161},"\u002Fen\u002Fblog\u002Fmodbus-protocol-integration","Modbus protocol integration",[18,164,166],{"id":165},"where-is-it-used","Where Is It Used?",[168,169,170,177,183,194],"ul",{},[171,172,173,176],"li",{},[26,174,175],{},"PLC I\u002FO expansion:"," Add digital inputs and outputs to your PLC over RS485.",[171,178,179,182],{},[26,180,181],{},"Remote I\u002FO:"," Collect sensors and buttons far from the cabinet on a single communication cable.",[171,184,185,188,189,193],{},[26,186,187],{},"HMI and SCADA control:"," Manage valves, motors and alarms from ",[38,190,192],{"href":191},"\u002Fen\u002Fsolutions\u002Fhmi-industrial-display-solutions","our HMI panels"," or a SCADA screen.",[171,195,196,199],{},[26,197,198],{},"Test and machine automation:"," Sequence control and status monitoring on test rigs.",[10,201,202],{},"Front-panel LEDs let you see the state of every input and output in the field at a glance.",[18,204,206],{"id":205},"quotes-and-information","Quotes and Information",[10,208,209,210,214,215,219],{},"See all of Conio's features on the ",[38,211,213],{"href":212},"\u002Fen\u002Fproducts\u002Fconio-modbus-digital-io-module","product page",". ",[38,216,218],{"href":217},"\u002Fen\u002Fcontact","Contact us"," for the channel count and output type that fit your project.",{"title":221,"searchDepth":222,"depth":222,"links":223},"",2,[224,225,226,227,228,229,230],{"id":20,"depth":222,"text":21},{"id":50,"depth":222,"text":51},{"id":124,"depth":222,"text":125},{"id":135,"depth":222,"text":136},{"id":146,"depth":222,"text":147},{"id":165,"depth":222,"text":166},{"id":205,"depth":222,"text":206},"Meet Conio, the newest member of the Amazeng product family: a digital I\u002FO module controlled over RS485 Modbus RTU, with 8 opto-isolated inputs \u002F 8 outputs as standard and 16 \u002F 16 channels as an option.","md",{"date":234,"author":235,"readTime":236,"tags":237,"image":16,"translation":243},"2026-11-11","Amazeng Technical Team",3,[238,239,154,240,241,242],"Conio","Digital I\u002FO","RS485","Remote I\u002FO","Industrial Automation","conio-modbus-dijital-io-modulu-tanitim",true,"\u002Fen\u002Fblog\u002Fintroducing-conio-modbus-digital-io-module",{"title":5,"description":231},"en\u002Fblog\u002Fintroducing-conio-modbus-digital-io-module","hCXAGvklI2REWuaJFp80DMPGX98CQCR20ExLn-WGzog",1795417505902]